Call Testing for MOC (In case of ATER call test)

Directed Call Test in MSS

Trunk to trunk test call

For trunk to trunk call e.g POI and Inter MSC call test we have to take a  B party test number first.

Then we have to define test case by following command :-

ZYCN::OUTROUT=Y,DIG=9716098909,CON=NAT,CONT=N,:;

Where DIG= B party number

If a testcase is already active deactivate it using the command ----- ZYCE:4:;

Now activate the newly created testcase with the command

ZYCS: ,4; 

Make the A party number in TP in HLR (from where you initiate the calls) with command

ZMIM:IMSI=:CAT=TP;

Now make the desired circuits in TE-ID mode with command

ZCEC:MGW=MSS01MGW0103,TERMID=10274-1&&-31,:TE; 

Now do test call and check the circuit with command ZMCJ:IMSI=;

Call Testing for MOC (In case of ATER call test)

In this case we can do test calls for ATER where A party has to initiate a call provided A party would be under the same  BSC for which call test is being done.

Then we have to define test case by following command :-

ZYCG::OUTROUT=Y,DIG=9716098909,CON=LOC,CONT=N,:;

Where DIG= B party number

If a testcase is already active deactivate it using the command ----- ZYCE:4:;

Now activate the newly created testcase with the command
styl� O s - 6 �� -weight: normal'> 

WORKING STATEOF UNITS
 UNIT       PHYS STATE LOCATION              INFO
 OMU-0      0000 SP-EX                        -                           
 OMU-1      0001 WO-EX                        -                           

TOTAL OF 2     UNITS

COMMAND EXECUTED

  
ZYCS: ,4; 

Make the A party number in TP in HLR (from where you initiate the calls) with command

ZMIM:IMSI=:CAT=TP;

Now make the desired circuits in TE-ID mode with command

ZCEC:MGW=MSS01MGW0103,TERMID=10274-1&&-31,:TE; 

Now do test call and check the circuit with command ZMCJ:IMSI=;


Call Testing for MTC (In case of ATER call test)

In this case we can do test calls for ATER where B party has to initiate a call provided B party would be under the same BSC for which call test is being done.

Then we have to define test case by following command :-

ZYCM:4:INROUT=Y,CONT=N,:

If a testcase is already active deactivate it using the command ----- ZYCE:4:;

Now activate the newly created testcase with the command

ZYCS: ,4; 

Make the B party number in TP in HLR (from where you initiate the calls) with command

ZMIM:IMSI=:CAT=TP;

Now make the desired circuits in TE-ID mode with command

ZCEC:MGW=MSS01MGW0103,TERMID=10274-1&&-31,:TE; 

Now do test call and check the circuit with command ZMCJ:IMSI=;