Ads Revenue Hits

Tuesday, September 16, 2014

BTS S/W check & Activate in BSC

ENTER USERNAME < BSCXXX

ENTER PASSWORD < ******

BSC3i     BSC83BRM                  2011-04-12  15:31:51















                       WELCOME TO THE DX 200 SERIES DIALOGUE





MAIN LEVEL COMMAND <___>
< ZEWO


LOADING PROGRAM VERSION 15.7-0

/*  DATA UNITS:

    NUMBER OF BCF;        */

EWO:126;

EXECUTION STARTED


BSC3i     BSC83BRM                  2011-04-12  15:32:04

BCF NUMBER      STATUS  BUILD-ID          VERSION    SUBDIR     STATE   SWMASTER
--------------------------------------------------------------------------------

BCF-0126          NW   EP3_MP3                  3.3-3      /PACK_17                
                           BU    EP3_MP2_BL0017    3.2-3      /PACK_16   DEFAULT
                           FB    FLEXI_EP1_0            1.0-1      /PACK_8          

COMMAND EXECUTED


BCF SOFTWARE HANDLING COMMANDS
< ZEWV

LOADING PROGRAM VERSION 15.7-0

/*  DATA UNITS:

    NUMBER OF BCF: BUILD STATUS;      */

EWV:126

/*  STATUS

    NW ... NEW
    BU ... BACK-UP
    FB ... FALL-BACK

    PARAMETER IS OBLIGATORY             */

EWV:126:NW;

EXECUTION STARTED

THIS COMMAND CUTS ALL ONGOING CALLS IN THE RESETED BTS SITE



CONFIRM COMMAND EXECUTION: Y/N ? Y

SOFTWARE BUILD ACTIVATED

BCF NUMBER       RESET            REASON FOR DENIAL
---------------------------------------------------------
BCF-0126         DENIED           O & M LINK STATE        

COMMAND EXECUTED


BCF SOFTWARE HANDLING COMMANDS
<


MAIN LEVEL COMMAND <___>
< EWO:126;

LOADING PROGRAM VERSION 15.7-0

EXECUTION STARTED


BSC3i     BSC83BRM                  2011-04-12  15:33:37

BCF NUMBER      STATUS  BUILD-ID          VERSION    SUBDIR     STATE   SWMASTER
--------------------------------------------------------------------------------

BCF-0126          NW   EP3_MP3                  3.3-3      /PACK_17   DEFAULT              
                           BU    EP3_MP2_BL0017    3.2-3      /PACK_16  
                           FB    FLEXI_EP1_0            1.0-1      /PACK_8          

COMMAND EXECUTED


MAIN LEVEL COMMAND <___>
< ZEWH


LOADING PROGRAM VERSION 15.7-0

/*  DATA UNITS:

    NUMBER OF BCF: FIRST STATUS, SECOND STATUS;         */
EWH:126

/*  STATUS

    PARAMETER NAMES:

    ST1  .....  FIRST STATUS         OBLIGATORY
    ST2  .....  SECOND STATUS        OBLIGATORY     */

EWH:126:ST1

/*  FIRST STATUS

    NW ... NEW
    BU ... BACK-UP
    FB ... FALL-BACK               */

EWH:126:ST1=BU

/*  STATUS

    PARAMETER NAMES:

    ST1  .....  FIRST STATUS         OBLIGATORY
    ST2  .....  SECOND STATUS        OBLIGATORY     */

EWH:126:ST1=BU,ST2

/*  SECOND STATUS

    NW ... NEW
    BU ... BACK-UP
    FB ... FALL-BACK               */

EWH:126:ST1=BU,ST2=NW

/*  STATUS

    PARAMETER NAMES:

    ST1  .....  FIRST STATUS         OBLIGATORY
    ST2  .....  SECOND STATUS        OBLIGATORY     */

EWH:126:ST1=BU,ST2=NW;

EXECUTION STARTED

SOFTWARE BUILD STATUSES CHANGED

BCF NUMBER      FIRST STATUS     SECOND STATUS
----------------------------------------------
BCF-0126             BU               NW

COMMAND EXECUTED


BCF SOFTWARE HANDLING COMMANDS
< ZEWO

LOADING PROGRAM VERSION 15.7-0

/*  DATA UNITS:

    NUMBER OF BCF;        */

EWO:126

/* SELECT EXECUTION DETERMINATION OR
   SYSTEM NAME OF OUTPUT DEVICE

     EXECUTION DETERMINATION:
       ; .. COMMAND EXECUTION
       N .. NO EXECUTION

     SYSTEM NAME OF OUTPUT DEVICE:
       1 ... 11 CHARACTERS

   DEFAULT IS CURRENT DEFINITION      */

EWO:126;

EXECUTION STARTED


BSC3i     BSC83BRM                  2011-04-12  15:35:14

BCF NUMBER      STATUS  BUILD-ID          VERSION    SUBDIR     STATE   SWMASTER
--------------------------------------------------------------------------------

BCF-0126          NW    EP3_MP2_BL0017    3.2-3      /PACK_16                
                           BU    EP3_MP3                    3.3-3      /PACK_17   DEFAULT
                           FB    FLEXI_EP1_0             1.0-1      /PACK_8          

COMMAND EXECUTED


BCF SOFTWARE HANDLING COMMANDS