NOKIA BSC COMMANDS
1. ZEEI ; - used to show the status of all sites in BSC
2. ZEEI :BCF=(bcf no); - used to check status of particular BCF
3. ZEOL:(BCF NO); - used to check alarm of particular Site.
4. ZQSI ; - used to check status of X.25 link
5. ZNEL; - to check status of all TCSM.
6. ZEFS:(bcf no):L/U; - used to lock/unlock BCF.
7. ZEQS:BTS=(BTS no):L/U; - used to lock and unlock sector.
8. ZERS:BTS=(BTS no):TRX=(TRx no):L/U; Used to lock/unlock individual TRx
9. ZEFR:BCF NUM:OMU/SITE; OMU/SITE RESET
10. ZAHO:ET,(ET.no) ; - To check alarm on ET. 30,37
11. ZUSC:ET,E.no:BL/WO; - Used for making ET block and working.
12. ZDTF:TCSM,E.no ; - State checking of ET.
13. ZEEL; -To see no. of calls continuing in a BSC
14. ZAHO; -To see all BSC related alarm
15. ZEOL:(BCF no); -To see all alarm related to one BCF
16. ZEOH:::BCF=BCF num; To see alarm history of a site
17. ZEOL::NR=7706; -To see all sites having OMU blocked
18. ZEOL::NR=7704; -To see all sites having PCM blocked
19. ZEOL::NR=7705; -To see all sites having LAPD failure
20. ZEOL::NR=7411; -To see all sites on battery
21. ZQUS(Enter twice):BCF=(BCF no):TRE=1:2;7(Enter)1(Enter)200(Enter) - To know the receiving power of a PDH link :ODU:
22. ZEEL:BCF(Enter)Select Option; -To know the blocked BCF/BTS/TRx category
21. ZIGO; - To know the MML application done with BSC since the last two remote session
23. ZYEF:ET,(ET no); - Checking loop in ET
24. ZEOH:yy-mm-dd:hh-mm-ss:bcf=(bcf no); - Alarm related to particular date and time
25. ZYMO:ET,E.no ; - to check slips on ET
26. ZZZZ; - to terminate a remote session
27. ZDSB:::PCM=(ET no); - To find BCF no from a ET no/ Shows D channel details
28. ZDTI:::PCM=(ET num); -To find D channel details
29. ZEOH::NR=7767; -To see the alarm num history in BSC for the last 00.00.00 hours
30. ZEOL::NR=7767; -To find out the sectors down in one BSC
31. ZQSC(ENTER)
QSC:0(ENTER)
QSC:0,UNL;(ENTER)
Command to change physical address
ZQSC(ENTER)
QSC:1(ENTER)
QSC:1,UNL;(ENTER)
32. ZQLG(ENTER)
QLG:0(ENTER)
QLG:0;X2(ENTER)
QLG:0:X25:UNL;(ENTER)
Command to change linkage
ZQLG(ENTER)
QLG:1(ENTER)
QLG:1;X2(ENTER)
QLG:1:X25:UNL;(ENTER)
Comment- If the X.25 link of BSC is locked from remote end the this command is used to unlock the X.25 link from local BSC end. Then both the command (28,29) should be executed
33. ZDSB:::PCM=(ET NO); To know wheather a ET is in use or not in use
34. ZWUP:ET NUM; - To know a ET type(TCSM/Abis)
35. ZQNI; -To know the numerical ID of a BSC
36. ZQRI:OMU; -To know the local IP allotted to BSC
37. ZAHP:::yyyy-mm-dd; -To know the alarm history of BSC
38. ZERO:BCF=(BCF NUM); -To know the TSC value for each trx
39. ZQWL:BCF=76; TO know the Q1 address of FIU s present in a site
40. ZEFO:BCF ID:IOP; To know the alarm configuration in a bts site
41. ZEFX:BCF NUM:INBR=alarm number:POL=OPEN/CLOSE; To change polarity of an external alarm
42. ZEFE: -External Alarm text modification command
43. ZDTC: D-channel name: BL/ WO; To change the state of D-channel
44. ZERC: Trx creation
45. ZERD: Trx Deletion (trx should be locked before deletion)
46. ZDSE: Lap-D creation